Home > Plastics > Materials > Mecoline > Mecoline S TP 1003 F - Datasheet

Mecoline S TP 1003 F Datasheet

Thermoplastic

Supplied by Melos GmbH

View Complete Data Sheet Search 115000+ Data Sheets
Create Your Free Account! or Login
Product Description
Halogen-free, low smoke, thermoplastic, highly flame retardant compound for the sheathing of low and medium voltage cables in General Installation applications.
General  
Material Status 
  • Commercial: Active
Availability 
  • Africa & Middle East
  • Asia Pacific
  • Europe
  • Latin America
  • North America
Additive 
  • Flame Retardant
Features 
  • Flame Retardant
  • Halogen Free
  • Low Smoke Emission
Uses 
  • Cable Jacketing
  • Low Voltage Insulation
  • Medium Voltage Insulation
  • Wire & Cable Applications
 
Wire Types 
  • HM2
  • HM4
  • LTS 1
  • LTS 4
  • SHF1
Agency Ratings 
RoHS Compliance 
Forms 
  • Pellets
Processing Method 
  • Extrusion
Physical
Nominal Value
Unit
Test Method
Density
g/cm³
ISO 1183/A
Melt Mass-Flow Rate (MFR) (150°C/21.6 kg)
g/10 min
ISO 1133
Water Absorption (73°F, 24 hr)
%
IEC 811-1-3
Water Absorption
     
after 240h at 70°C
mg/cm²
IEC 811-1-3
after 24h at 23°C
mg/cm²
ASTM D570
Mooney Viscosity (ML 1+4, 284°F)
MU
DIN 53523
pH
 
IEC 60754-2
Mechanical
Nominal Value
Unit
Test Method
Tensile Stress
psi
IEC 811-1-1
Tensile Strain (Break)
%
IEC 811-1-1
Abrasion
mm³
VDE 0472
Hardness
Nominal Value
Unit
Test Method
Shore Hardness (Shore D)
 
ISO 7619
Thermal
Nominal Value
Unit
Test Method
Hot Pressure Test
    IEC 811-3-1
penetration 6h at 100°C
%
 
penetration 6h at 90°C
%
 
Temperature Index
°F
ASTM D2863
Aging
Nominal Value
Unit
Test Method
Change in Tensile Strength in Air
    IEC 811-1-2
212°F, 240 hr
%
 
230°F, 168 hr
%
 
Change in Tensile Strain at Break in Air
    IEC 811-1-2
212°F, 240 hr
%
 
230°F, 168 hr
%
 
Electrical
Nominal Value
Unit
Test Method
Volume Resistivity 2
ohms·cm
DIN VDE 0303
Dielectric Constant (50 Hz)
 
IEC 60250
Dissipation Factor (50 Hz)
 
IEC 60250
Conductivity
µS/mm
 
Flammability
Nominal Value
Unit
Test Method
Oxygen Index
%
ASTM D2863
Smoke Density
    ASTM E662
Flaming mode
 
 
Non-flaming mode
 
 
Toxicity
 
NES 713
Additional Information
Nominal Value
Unit
Test Method
Tear Strength
psi
BS 6469 99.1
Features
Features may also be described by the following terms: Zero Halogen Content, Halogen Free, Low Smoke Emission.
Uses
Uses may also be described by the following terms: Low Voltage Insulation, Medium Voltage Insulation, Wire and Cable Applications, Wire & Cable Applications.
Agency Ratings
This plastic material has 11 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): NFC (1), VDE (5), BS (2), EN (1), CEI (1), IEC (1).
Available Documents
Technical Datasheet (English)
Extrusion
Nominal Value
Unit
 
Cylinder Zone 1 Temp.
°F
 
Cylinder Zone 2 Temp.
°F
 
Cylinder Zone 3 Temp.
°F
 
Cylinder Zone 4 Temp.
°F
 
Cylinder Zone 5 Temp.
°F
 
Adapter Temperature
°F
 
Head Temperature
°F
 
Die Temperature
°F
 
Extruder Screw L/D Ratio
 
 
Extruder Screw Compression Ratio
 
 
Notes
1Typical properties: these are not to be construed as specifications.
216h at 20°C, 500V
 
UL and the UL logo are trademarks of UL LLC © 2016. All Rights Reserved.
The information presented on this datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.