Home > Plastics > Materials > Durethan® > Durethan® DP 2801 000000 - Datasheet

Durethan® DP 2801 000000 Datasheet

Polyamide 66

Supplied by LANXESS Corporation

View Complete Data Sheet Search 118000+ Data Sheets
Create Your Free Account! or Login
Product Description
Durethan® 
DP 2801 000000
(Dry)
PA 66, non-reinforced, injection molding, halogen free flame retardant
Durethan® 
DP 2801 000000
PA 66, non-reinforced, injection molding, halogen free flame retardant
Durethan® 
DP 2801 000000
PA 66, non-reinforced, injection molding, halogen free flame retardant
General Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Manufacturers 
  • LANXESS Corporation
  • LANXESS GmbH
  • LANXESS Asia/Pacific
Classification 
  • Nylon 66
  • Nylon 66
  • Nylon 66
Material Status 
  • Commercial: Active
  • Commercial: Active
  • Commercial: Active
Availability 
  • Latin America
  • North America
  • Africa & Middle East
  • Europe
  • Asia Pacific
Additive 
--
  • Flame Retardant
  • Flame Retardant
Features 
  • Flame Retardant
  • Halogen Free
  • Flame Retardant
  • Halogen Free
  • Flame Retardant
  • Halogen Free
Agency Ratings 
--
Processing Method 
  • Injection Molding
  • Injection Molding
  • Injection Molding
Resin ID (ISO 1043)
--
--
  • PA FR (30)
Physical Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Density (73°F)
--
g/cm³
ISO 1183
Molding Shrinkage
           
Across Flow : 500°F, 0.0787 in 2
--
--
--
%
ISO 2577
Across Flow : 536°F, 0.0787 in 2
--
--
--
%
ISO 2577
Across Flow : 536°F, 0.0787 in 3
--
--
--
%
ISO 294-4
Across Flow : 248°F, 2 hr, 0.0787 in 4
--
--
--
%
ISO 294-4
Across Flow : 248°F, 4 hr, 0.0787 in 5
--
--
%
ISO 2577
Flow : 500°F, 0.0787 in 2
--
--
--
%
ISO 2577
Flow : 536°F, 0.0787 in 3
--
--
--
%
ISO 294-4
Flow : 536°F, 0.0787 in 2
--
--
--
%
ISO 2577
Flow : 248°F, 2 hr, 0.0787 in 4
--
--
--
%
ISO 294-4
Flow : 248°F, 4 hr, 0.0787 in 5
--
--
%
ISO 2577
Mechanical Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Tensile Modulus (73°F)
psi
ISO 527-2/1
Tensile Stress
           
Yield, 73°F
psi
ISO 527-2/50
Break, 73°F
psi
ISO 527-2/5
Tensile Strain
           
Yield, 73°F
%
ISO 527-2/50
Break, 73°F
%
ISO 527-2/5
Nominal Tensile Strain at Break (73°F)
%
ISO 527-2/50
Flexural Modulus 6 (73°F)
psi
ISO 178/A
Flexural Stress
           
3.5% Strain 6
--
--
psi
ISO 178/A
3.5% Strain, 73°F
--
--
--
psi
ISO 178/A
73°F 6
--
--
psi
ISO 178
73°F 6
--
--
psi
ISO 178/A
3.5% Strain, 73°F 6
--
--
--
psi
ISO 178/A
Flexural Strain at Flexural Strength
           
73°F 7
--
--
%
 
73°F 8
--
--
%
ISO 178/A
Films Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Film Puncture Energy
          ISO 6603-2
-- 9
--
--
in·lb
 
-- 10
--
--
--
in·lb
 
Film Puncture Force
          ISO 6603-2
-- 9
--
--
lbf
 
-- 10
--
--
--
lbf
 
Impact Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Charpy Notched Impact Strength
          ISO 179/1eA
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Charpy Unnotched Impact Strength
          ISO 179/1eU
-22°F
ft·lb/in²
 
73°F
 
 
Notched Izod Impact Strength
          ISO 180/1A
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Unnotched Izod Impact Strength
          ISO 180/1U
-22°F
ft·lb/in²
 
73°F
 
 
Multi-Axial Instrumented Impact Energy
          ISO 6603-2
-22°F
--
--
ft·lb
 
73°F
--
--
ft·lb
 
Multi-Axial Instrumented Impact Peak Force
          ISO 6603-2
-22°F
--
--
lbf
 
73°F
--
--
lbf
 
Hardness Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Ball Indentation Hardness
psi
ISO 2039-1
Thermal Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Heat Deflection Temperature
           
66 psi, Unannealed
--
°F
ISO 75-2/B
264 psi, Unannealed
--
°F
ISO 75-2/A
1160 psi, Unannealed
--
°F
ISO 75-2/C
Vicat Softening Temperature
--
°F
ISO 306/B120
Ball Pressure Test (480°F)
--
 
IEC 60695-10-2
Melting Temperature 11
--
°F
ISO 11357-3
CLTE
          ISO 11359-2
Flow : 73 to 131°F
--
in/in/°F
 
Transverse : 73 to 131°F
--
in/in/°F
 
Electrical Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Comparative Tracking Index
          IEC 60112
Solution A
--
V
 
Solution B 12
--
V
 
Flammability Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Flame Rating
          UL 94
0.030 in
--
 
 
0.06 in
--
--
--
 
 
0.12 in
--
--
--
 
 
Glow Wire Flammability Index
          IEC 60695-2-12
0.030 in
--
--
--
°F
 
0.04 in
--
--
°F
 
0.06 in
--
--
--
°F
 
0.12 in
--
--
--
°F
 
Glow Wire Ignition Temperature
          IEC 60695-2-13
0.030 in
--
°F
 
0.06 in
--
°F
 
0.12 in
--
°F
 
Oxygen Index 13
--
%
ISO 4589-2
Burning Behavior 14 (> 39.4 mil)
--
 
ISO 3795
Additional Information Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
(Conditioned)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
ISO Shortname
--
 
ISO 1874
Related Terminology
Durethan® 
DP 2801 000000
(Dry)
This supplier and product may also be known by these terms: Durathan, PA66
Durethan® 
DP 2801 000000
(Conditioned)
This supplier and product may also be known by these terms: Durathan, PA66
Durethan® 
DP 2801 000000
This supplier and product may also be known by these terms: Durathan, PA66
Durethan® 
DP 2801 000000
This supplier and product may also be known by these terms: Durathan, PA66
Generic Name
Durethan® 
DP 2801 000000
(Dry)
Generic Name may also be described by the following terms: PA66.
Durethan® 
DP 2801 000000
(Conditioned)
Generic Name may also be described by the following terms: PA66.
Durethan® 
DP 2801 000000
Generic Name may also be described by the following terms: PA66.
Durethan® 
DP 2801 000000
Generic Name may also be described by the following terms: PA66.
Features
Durethan® 
DP 2801 000000
(Dry)
Features may also be described by the following terms: Zero Halogen Content, Halogen Free.
Durethan® 
DP 2801 000000
Features may also be described by the following terms: Zero Halogen Content, Halogen Free.
Durethan® 
DP 2801 000000
Features may also be described by the following terms: Zero Halogen Content, Halogen Free.
Agency Ratings
Durethan® 
DP 2801 000000
(Dry)
This plastic material has 1 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): EC (1).
Durethan® 
DP 2801 000000
This plastic material has 1 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): EC (1).
Available Documents
Durethan® 
DP 2801 000000
(Dry)
Processing - Durethan (English)
Technical Datasheet - ASTM (English)
Technical Datasheet - ISO (English)
Durethan® 
DP 2801 000000
Processing - Durethan (English)
Technical Datasheet (English)
Durethan® 
DP 2801 000000
Processing - Durethan (English)
Technical Datasheet (English)
Injection Durethan® 
DP 2801 000000
(Dry)
Durethan® 
DP 2801 000000
Durethan® 
DP 2801 000000
Unit
Test Method
Drying Temperature - Dry Air Dryer
°F
 
Drying Time - Dry Air Dryer
hr
 
Processing (Melt) Temp
°F
 
Mold Temperature
°F
 
Admissible Residence Time at Tmax
min
 
Residual Moisture Content
%
Karl Fisher
Notes
1Typical properties: these are not to be construed as specifications.
260x60x2mm, 80°C MT, 600 bar
360x60x2; MT 80°C; 600 Bar
460x60x2
560x60x2mm
60.079 in/min
7Pull Rate: 2 mm/min; 50% RH
82 mm/min
923°C
10-30°C
1110°C/min
12Depth of Erosion: 0.0709 in
13Procedure A
14US-FMVSS302
 
UL and the UL logo are trademarks of UL LLC © 2016. All Rights Reserved.
The information presented on this datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.