ACLAR® 88A (0.75 mil) Datasheet

Polychlorotrifluoroethylene

Supplied by Honeywell

Create your free Prospector account to view this complete product datasheet. A free account includes access to hundreds of thousands of detailed technical datasheets. Create Your Free Account
Product Description
ACLAR® 88A (0.75 mil) is a Polychlorotrifluoroethylene (PCTFE) product. It can be processed by cast film and is available in Asia Pacific, Europe, or North America. Typical application: Medical/Healthcare. Primary characteristic: copolymer.
General  
Material Status 
  • Commercial: Active
Availability 
  • Asia Pacific
  • Europe
  • North America
Features 
  • Barrier Resin
  • Copolymer
 
Uses 
  • Medical Packaging
Forms 
  • Pellets
Processing Method 
  • Cast Film
Physical
Nominal Value
Unit
Test Method
Density
g/cm³
ASTM D1505
Films
Nominal Value
Unit
Test Method
Secant Modulus
    ASTM D882
MD : 0.75 mil
psi
 
TD : 0.75 mil
psi
 
Tensile Strength
    ASTM D882
MD : Yield, 0.75 mil
psi
 
TD : Yield, 0.75 mil
psi
 
Tensile Elongation
    ASTM D882
MD : Yield, 0.75 mil
%
 
TD : Yield, 0.75 mil
%
 
Water Vapor Transmission
g/100 in²/24 hr
ASTM E96
Optical
Nominal Value
Unit
Test Method
Haze (0.750 mil)
%
ASTM D1003
Additional Information
Yield, No Standard: 25.28 m²/kg
Tear Strength, ASTM D1004, Graves MD: 300 to 350 g/mil
Tear Strength, ASTM D1004, Graves TD: 250 to 325 g/mil
Crystalline Melting Point, ASTM D4591: 195 °C
Dimensional Stability, ASTM D1204, MD: 12 to 15 %
Dimensional Stability, ASTM D1204, TD: -12 to -15 %
All film properties were tested as an average value.
Uses
Uses may also be described by the following terms: Medical Packaging.
Notes
1Typical properties: these are not to be construed as specifications.
 
UL and the UL logo are trademarks of UL LLC © 2021. All Rights Reserved.
The information presented here was acquired by UL from the producer of the product or material or original information provider. However, UL assumes no responsibility or liability for the accuracy of the information contained on this website and strongly encourages that upon final product or material selection information is validated with the manufacturer. This website provides links to other websites owned by third parties. The content of such third party sites is not within our control, and we cannot and will not take responsibility for the information or content.