Descripción del Producto | ||||
DESCRIPTION: Random copolymer for injection molding.
FEATURES: Produced without animal derived components. STERILIZATION: Gamma radiation, ETO, E-beam and autoclave. APPLICATIONS: Medical device components, labware, closures. |
||||
General | ||||
Estado del Material
|
|
|||
Disponibilidad
|
|
|||
Características
|
|
|||
Usos
|
|
|||
Clasificaciones de Agencia
|
|
|||
Conformidad con RoHS
|
|
|||
Formas
|
|
|||
Método de Procesamiento
|
|
Prop. físicas |
Valor Típico
|
Unidad
|
Método de Ensayo
|
Densidad
|
|
g/cm³
|
ASTM D1505 |
Velocidad de Fundido (230°C/2,16 kg)
|
|
g/10 min
|
ASTM D1238 |
Prop. mecánicas |
Valor Típico
|
Unidad
|
Método de Ensayo
|
Tensión (Punto de Fluencia)
|
|
psi
|
ASTM D638 |
Elongación (Punto de Fluencia)
|
|
%
|
ASTM D638 |
Módulo de Flexión -
Tangente
|
|
psi
|
ASTM D790 |
Impacto |
Valor Típico
|
Unidad
|
Método de Ensayo
|
Resistencia al Impacto Izod con ranura (73°F)
|
|
ft·lb/in
|
ASTM D256 |
Impacto Gardner (73°F)
|
|
in·lb
|
ASTM D5420 |
Dureza |
Valor Típico
|
Unidad
|
Método de Ensayo
|
Dureza Rockwell (Escala R)
|
|
|
ASTM D785 |
Prop. térmicas |
Valor Típico
|
Unidad
|
Método de Ensayo
|
Temperatura de deflexión bajo carga (66 psi, No recocido)
|
|
°F
|
ASTM D648 |
Temperatura de Fusión
|
|
°F
|
ASTM D3418 |
Información adicional | |||
Notice regarding medical applications:
This Flint Hills product meets certain requirements for use in medical applications. It is the responsibility of the medical device or pharmaceutical manufacturer to determine that this Flint Hills product is safe, lawful and technically suitable for the intended use. Flint Hills encourages its customers to review their application with a Flint Hills technical representative to ensure that this product is not used in ways for which it was not intended. Flint Hills makes no warranties (express or implied), promises or guarantees concerning the suitability of this product for use in any given medical application. |
|||
Características | |||
Características may also be described by the following terms: Random Copolymer, Radiation Sterilizable, Radiation Sterilization, gamma sterilization, gamma sterilizable, ADC, Animal Derived Materials, ADM, Animal Free, ADM Free, Non-ADM, Autoclave Sterilization, Autoclave Sterilizable, e-beam Sterilization, E-beam Sterilizable, electron beam, electron-beam, electron beam radiation, e-beam radiation, Ethylene Oxide Sterilizable, EtO Sterilizable, EtO Sterilization, Ethylene Oxide Sterilizable.
|
|||
Usos | |||
Usos may also be described by the following terms: Medical Appliances, Medical Devices, Labware, Closures.
|
|||
Clasificaciones de Agencia | |||
This plastic material has 7 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): DMF (1), ISO (1), USP (3), FDA (2).
|
|||
Available Documents | |||
Technical Datasheet (English)
|
Notas |
1Propiedades típicas: éstas no deben interpretarse como especificaciones. |
UL y el logo de UL son marcas comerciales de UL LLC © 2021. Todos los derechos reservados.
La información presentada en este boletín técnico ha sido adquirida por UL Prospector del productor del material. UL Prospector realiza considerables esfuerzos para garantizar la exactitud de estos datos. No obstante, UL Prospector no asume responsabilidad alguna por los valores de los datos y recomienda encarecidamente que los datos del material se confirmen con el proveedor antes de la selección final. |