Polymère de cristal liquide (LCP) by Celanese Corporation
Product | Availability | Product Description |
---|---|---|
CoolPoly® D5506 | África y Oriente Medio |
CoolPoly D5506 is a thermally conductive, highly electrically insulative LCP based grade
CoolPoly D series of thermally conductive plastics transfers heat, a characteristic previously unavailable in injection molding grade polymers. CoolPoly is lightweight, netshape moldable and allows design freedom in applications previously restricted to metals. The D series is electrically non-conductive and can be used for its dielectric properties.
|
CoolPoly® D5522 | África y Oriente Medio |
Thermally conductive LCP for thin wall applications.
CoolPoly® D5522 offers thermal conductivity, excellent mechanical strength, surface appearance, low warpage, and excellent dimensional stability. Application for this grade is for a part with thin wall design in automotive and electronics. The D series is electrically non-conductive and can be used for its dielectric properties.
|
CoolPoly® D5526 | África y Oriente Medio |
Thermally conductive LCP for thin wall applications.
CoolPoly® D5526 offers thermal conductivity, excellent mechanical strength, surface appearance, low warpage, and excellent dimensional stability. Application for this grade is for a part with thin wall design in automotive and electronics. The D series is electrically non-conductive and can be used for its dielectric properties.
|
CoolPoly® E2 | África y Oriente Medio |
CoolPoly E2 is a thermally and electrically conductive high strength LCP based flame retardant grade
|
CoolPoly® E5521 | África y Oriente Medio |
Thermally Conductive Liquid Crystal Polymer
CoolPoly E series of thermally conductive plastics transfers heat, is lightweight, netshape moldable and allows design freedom in applications previously restricted to metals.
|
Vectra® A115 | África y Oriente Medio |
15% glass fiber, provides easier flow than A130, Tougher
Provides easier flow than A130. Slightly tougher, but may warp slightly more than A130 in some parts. 15% glass reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.44mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 240°C, mechanicals 220°C at 0.85mm. UL = Underwriters Laboratories (USA)
|
Vectra® A130 | África y Oriente Medio |
30% glass fiber, exc. bal. of properties
The Standard for the Industry. Excellent balance of properties, including easy flow, easy processing, thermal stability, chemical resistance, mechanical and electrical properties. Suitable for vapor phase surface mount electrical and electronic devices. 30% glass reinforced Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.2mm thickness per UL 94 flame testing, and UL-5VA in natural at 1.5mm. Relative-Temperature-Index (RTI) according to UL 746B: electricals 240°C, mechanicals 220°C at 0.85mm. UL = Underwriters Laboratories (USA)
|
Vectra® A230 | África y Oriente Medio |
30% carbon fiber, conductive
Exceptional stiffness. Electrically conductive. 30% carbon fiber reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 at 0.43mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A240 | África y Oriente Medio |
40% carbon fiber reinforced grade with excellent electrical conductivity and exceptional stiffness. Â
|
Vectra® A430 | África y Oriente Medio |
LCP/PTFE, excellent wear & electrical properties at high frequencies
Provides many of the characteristics of A130 with added lubricity. Suitable for applications requiring excellent wear characteristics. Excellent electrical properties at high frequencies. LCP/PTFE blend. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.43mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A435 | África y Oriente Medio |
Glass/PTFE, best High Arc Ignition performance
Best High Current Arc Ignition (HAI) performance. Glass/PTFE filled. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant. UL-Listing V-0 in natural at 044mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A515 | África y Oriente Medio |
15% mineral filled
Easier flow and slightly improved toughness over A530. Outstanding hydrolytic stability. 15% mineral filled. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural at 0.38mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A530 | África y Oriente Medio |
30% mineral , hydrolytically stable
Best overall surface appearance with properties similar to A130. Less abrasive than glass fiber reinforced grades. Improved toughness over A130. Outstanding hydrolytic stability. Recommended where aesthetics are key. 30% mineral filled. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.38mm thickness per UL 94 flame testing, and UL-5VA in natural at 3.0mm. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A625 | África y Oriente Medio |
25% graphite, good wear characteristics
Good wear characteristics. 25% graphite filled. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 at 0.45mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C.. UL = Underwriters Laboratories (USA)
|
Vectra® A700 | África y Oriente Medio |
30% glass fiber, suitable for electrostatic dissipation (ESD)
Some conductivity. Suitable for electrostatic dissipation (ESD) applications. 30% glass reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 at 0.42mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A725 | África y Oriente Medio |
25% filled, conductive grade
Conductive Vectra grade, smooth surface compared to A700. 25% filled grade. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 at 0.83mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® A950 | África y Oriente Medio |
suitable for extrusion
Unreinforced Vectra grade suitable for extrusion. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant FDA compliant. UL-Listing V-0 in natural and black at 0.42mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 240°C, mechanical 220°C. UL = Underwriters Laboratories (USA)
|
Vectra® B230 | África y Oriente Medio |
30% carbon fiber, exceptional strength and stiffness, conductive
Exceptional strength and stiffness. Suitable for metal replacement applications. Electrically conductive. 30% carbon fiber reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 at 0.46mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® C130 | África y Oriente Medio |
30% glass fiber, higher temp. capability & easier flow than A130
Has the same excellent balance of properties as A130 with higher temperature capability and easier flow. Slightly more dimensional stability in vapor phase soldering than A130. Suitable for some infrared SMT applications. 30% glass reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.38mm thickness per UL 94 flame testing, and UL-5VA in natural at 1.5mm. Relative-Temperature-Index (RTI) according to UL 746B: electrical 240°C, mechanical 220°C at 0.75mm. UL = Underwriters Laboratories (USA)
|
Vectra® C950 | África y Oriente Medio |
Vectra C950 is an unreinforced; inherently flame retardant Vectra grade suitable for extrusion. UL-Listing V-0 in natural at 0.81mm thickness per UL 94 flame testing.
Vectra C950 is an unreinforced Vectra grade suitable for extrusion Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant FDA compliant UL-Listing V-0 in natural at 0.81mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 240°C, mechanical 220°C. UL = Underwriters Laboratories (USA)
|
Vectra® E115i | África y Oriente Medio |
15% Glass Reinforced
15% glass reinforced Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant. UL-Listing V-0 black at 0.75mm thickness per UL 94 flame testing. UL = Underwriters Laboratories (USA)
|
Vectra® E130G | África y Oriente Medio |
30% glass fiber filled/low injection pressure
30% glass fiber filled / low injection pressure Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.75mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 130°C, mechanicals 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® E130i | África y Oriente Medio |
30% glass fiber, excellent flow, high temperature capability
High temperature capability, easiest flow. Suitable where very thin walls are required. Used for broad range of SMT applications, with minimal dimensional change. 30% glass filled. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at .2mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 240°C, mechanical 240°C at 0.75mm. UL = Underwriters Laboratories (USA)
|
Vectra® E135i | África y Oriente Medio |
Higher weldline strength, 35% glass filled
35% glass fiber filled /Higher weldline strength. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant. UL-Listing V-0 in all colors at .15mm thickness per UL 94 flame testing. UL = Underwriters Laboratories (USA)
|
Vectra® E150i | África y Oriente Medio |
50% glass fiber, good flow, high temperature capability
Easy flowing grade with very good heat resistance, and mechanical properties. May reduce warpage in some parts compared to E130i. 50% glass reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.43mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 240°C, mechanicals 240°C at 0.75mm. UL = Underwriters Laboratories (USA)
|
Vectra® E440i | África y Oriente Medio |
Mineral and glass filled grade with low warp, easy flow and smooth surface appearance.
Mineral and glass filled grade with low warp, easy flow and smooth surface appearance. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant.
|
Vectra® E463i | África y Oriente Medio |
40% glass/mineral filled excellent flow, low warpage, high heat resistance.
40% glass/mineral filled excellent flow, low warpage, high heat resistance. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 all colors at 1.5mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 130°C, mechanicals 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® E471i | África y Oriente Medio |
Low warp with excellent properties
35% GF/Min modified/reinforced, low warp Vectra LCP grade with excellent properties Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant. UL-Listing V-0 at all color at 0.15mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 130°C, mechanicals 130°C. UL = Underwriters Laboratories
|
Vectra® E473i | África y Oriente Medio |
Vectra E473i is a low warp LCP with easy flow and high temperature capability.
Vectra E473i is a low warp LCP with easy flow and high temperature capability. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural and black at 0.75mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 130°C, mechanicals 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® E488i | África y Oriente Medio |
Ultra low warp
Ultra low warp
|
Vectra® E531i | África y Oriente Medio |
Mineral filled grade with low warp, easy flow and smooth surface appearance
Mineral filled grade with low warp, easy flow and smooth surface appearance. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant
|
Vectra® E540i | África y Oriente Medio |
40% mineral, low warp & easy flow with smooth surface appearance
Mineral filled grade with low warp, easy flow and smooth surface appearance. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant. UL-Listing V-0 in natural and black at1.5mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C. UL = Underwriters Laboratories (USA)
|
Vectra® E820iPd | África y Oriente Medio |
40 % mineral , excellent flow, electrolytic metal platable
Catalytically modified E820i Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in natural at 1.5mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electrical 130°C, mechanical 130°C at 1.5mm. UL = Underwriters Laboratories (USA)
|
Vectra® E830iPd | África y Oriente Medio |
30% glass filled Platable grade.
30% glass filled Platable grade. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant.
|
Vectra® E840i LDS | África y Oriente Medio |
40% Mineral filled Laser Direct Structuring grade.
40% Mineral filled Laser Direct Structuring grade. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in black at 1.5mm thickness per UL 94 flame testing. UL = Underwriters Laboratories (USA)
|
Vectra® E845i LDS | África y Oriente Medio |
LDS capable LCP with higher DTUL and impact
LDS capable LCP with higher DTUL and impact Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant UL-Listing V-0 in black a 0.25mm thickness per UL 94 flame testing. UL = Underwriters Laboratories (USA)
|
Vectra® FIT30 | África y Oriente Medio |
Glass and mineral filled grade, high flow and low warpage
43% glass and mineral reinforced grade. Glass and mineral filled grade, high flow and low warpage. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant
|
Vectra® FIT50 | África y Oriente Medio |
Vectra®Â FIT 50 is a 30% mineral reinforced liquid crystal polymer for injection molding. It has excellent filling capability and extremely low warpage performance in long and thin wall complicated applications.
|
Vectra® J540 | África y Oriente Medio |
40% Mineral filled; high heat resistance.
40% Mineral filled, high heat resistance. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant
|
Vectra® J543 VD3071 Cosmos Black | África y Oriente Medio |