Access over 120,000 technical material datasheets with Prospector! Create Your Free Account

Flammability Classification - IEC 60695-11-10

Horizontal Testing (HB) - Method A

Procedure: A specimen is supported in a horizontal position and is tilted at 45°. A flame is applied to the end of the specimen for 30 seconds or until the flame reaches the 1 inch mark. If the specimen continues to burn after the removal of the flame, the time for the specimen to burn between the 1 and 4 inch marks are recorded. If the specimen stops burning before the flame spreads to the 4 inch mark, the time of combustion and damaged length between the two marks is recorded. Three specimens are tested for each thickness.


Horizontal Flame Test

Horizontal Rating Requirements
HB
  • Specimens must not have a burning rate greater than 1.5 inches/minute for thicknesses between 0.120 and 0.500 inches and 3 inches/minute for thicknesses less than 0.120 inches.
  • Specimens must stop burning before the flame reaches the 4 inch mark.

Vertical Testing (V-0, V-1, V-2) - Method B

Procedure: A specimen is supported in a vertical position and a flame is applied to the bottom of the specimen. The flame is applied for ten seconds and then removed until flaming stops at which time the flame is reapplied for another ten seconds and then removed. Two sets of five specimens are tested. The two sets are conditioned under different conditions.


Vertical Flame Test

Vertical Ratings Requirements
V-0
  • Specimens must not burn with flaming combustion for more than 10 seconds after either test flame application.
  • Total flaming combustion time must not exceed 50 seconds for each set of 5 specimens.
  • Specimens must not burn with flaming or glowing combustion up to the specimen holding clamp.
  • Specimens must not drip flaming particles that ignite the cotton.
  • No specimen can have glowing combustion remain for longer than 30 seconds after removal of the test flame.
V-1
  • Specimens must not burn with flaming combustion for more than 30 seconds after either test flame application.
  • Total flaming combustion time must not exceed 250 seconds for each set of 5 specimens.
  • Specimens must not burn with flaming or glowing combustion up to the specimen holding clamp.
  • Specimens must not drip flaming particles that ignite the cotton.
  • No specimen can have glowing combustion remain for longer than 60 seconds after removal of the test flame.
V-2
  • Specimens must not burn with flaming combustion for more than 30 seconds after either test flame application.
  • Total flaming combustion time must not exceed 250 seconds for each set of 5 specimens.
  • Specimens must not burn with flaming or glowing combustion up to the specimen holding clamp.
  • Specimens can drip flaming particles that ignite the cotton.
  • No specimen can have glowing combustion remain for longer than 60 seconds after removal of the test flame.

Similar Standards